Motor model | Specs | Output Power W |
Voltage V |
Frequency Hz |
Current A |
Starting Torque | Rated Torque | Rated Revolution r/min |
Capacity/Ve μ F/VAC |
||
JWD types | mN.m | gf. cm | mN.m | gf. cm | |||||||
6IK120GU-CF 6IK120A-CF |
Induction | 120 | 1-phase 220 |
50 | 1.0 | 1100 | 11000 | 880 | 8800 | 1350 | 6/450 |
60 | 1.0 | 925 | 9250 | 740 | 7400 | 1550 | 6/450 | ||||
6RK120GU-CF 6RK120A-CF |
Reversible | 50 | 1.2 | 1575 | 15750 | 1260 | 12600 | 1350 | 8/450 | ||
60 | 1.4 | 1225 | 12250 | 980 | 9800 | 1550 | 8/450 | ||||
6IK120GU-AF 6IK120A-AF |
Induction | 120 | 1-phase 110 |
50 | 1.7 | 1100 | 11000 | 880 | 8800 | 1350 | 30/250 |
60 | 1.6 | 925 | 9250 | 740 | 7400 | 1550 | 28/250 | ||||
6RK120GU-AF 6RK120A-AF |
Reversible | 50 | 1.8 | 1575 | 15750 | 1260 | 12600 | 1350 | 32/250 | ||
60 | 2.0 | 1225 | 12250 | 980 | 9800 | 1550 | 32/250 | ||||
6IK120GU-UF 6IK120A-UF |
120 | 3-phase 380 |
50 | 0.46 | 1100 | 11000 | 880 | 8800 | 1350 | ||
60 | 0.42 | 925 | 9250 | 740 | 7400 | 1550 | |||||
6RK120GU-SF 6RK120A-SF |
120 | 3-phase 220 |
50 | 0.8 | 1100 | 11000 | 880 | 8800 | 1350 | ||
60 | 0.73 | 925 | 9250 | 740 | 7400 | 1550 | |||||
6IK140GU-CF 6IK140A-CF |
Induction | 140 | 1-phase 220 |
50 | 1.23 | 1285 | 12850 | 1028 | 10280 | 1350 | 8/450 |
60 | 1.12 | 1078 | 10780 | 863 | 8630 | 1550 | 8/450 | ||||
6RK140GU-CF 6RK140A-CF |
Reversible | 50 | 1.3 | 1285 | 12850 | 1028 | 10280 | 1350 | 10/450 | ||
60 | 1.43 | 1078 | 10780 | 863 | 8630 | 1550 | 10/450 | ||||
6IK140GU-AF 6IK140A-AF |
Induction | 140 | 1-phase 110 |
50 | 2.05 | 1285 | 12850 | 1028 | 10280 | 1350 | 32/250 |
60 | 1.9 | 1078 | 10780 | 863 | 8630 | 1550 | 30/250 | ||||
6RK140GU-AF 6RK140A-AF |
Reversible | 50 | 2.2 | 1285 | 12850 | 1028 | 10280 | 1350 | 40/250 | ||
60 | 2.4 | 1078 | 10780 | 863 | 8630 | 1550 | 32/250 | ||||
6RK140GU-UF 6RK140A-UF |
140 | 3-phase 380 |
50 | 0.55 | 1285 | 12850 | 1028 | 10280 | 1350 | ||
60 | 0.46 | 1078 | 10780 | 863 | 8630 | 1550 | |||||
6RK140GU-SF 6RK140A-SF |
140 | 3-phase 220 |
50 | 0.88 | 1285 | 12850 | 1028 | 10280 | 1350 | ||
60 | 0.80 | 1078 | 10780 | 863 | 8630 | 1550 |
●Parameters in the above table refer to the motor alone, without any load device.
●Permissible change in rated speed and rated current of the motor is within the range of土5%.
Geared-down parameter |
Synchronous speed | 500 | 300 | 200 | 150 | 120 | 100 | 83 | 75 | 60 | 50 | 41 | 37 | 30 | 25 | 20 | 15 | 12 | 10 | 8 | 7 | 6 | 5 | 3 | |
ratio | 3 | 5 | 7.5 | 10 | 12.5 | 15 | 18 | 20 | 25 | 30 | 36 | 40 | 50 | 60 | 75 | 100 | 120 | 150 | 180 | 200 | 250 | 300 | 500 | ||
Max allowable load |
120W | kg. cm N.m |
21.5 2.11 |
36 3.52 |
54 5.28 |
69.8 6.85 |
85 8.45 |
103 10.2 |
125 12.3 |
139 13.6 |
172 16.9 |
209 20.5 |
226 22.14 |
251 24.6 |
315 31 |
||||||||||
140W | kg. cm N.m |
25.1 2.46 |
42 4.11 |
63 6.16 |
73.5 8.02 |
99.2 9.86 |
120 11.8 |
132 121 |
147 14.4 |
200.7 19.73 |
221 21.7 |
238 23.4 |
265 26 |
330 32.5 |
●The speed is based on the synchronous motor speed reduction ratio as a benchmark calculated by dividing the value. Actual speed will vary the size of the load changes in less than the values shown in2~1 5%.
●Hope the table of the reduction ratio is greater than the further reduction, it would be installed between the motor and the reducer reduction ratio of 10 in the middle of the reducer.
●When the load torque exceeds the maximum allowable load torque gear motor, and a locked rotor situation exists, please slow down the box at the junction of the output shaft and load torque limit device installed to ensure the normal operation gearbox.